TVD.

Plugs

262155-C1-eth_ep-rlt_h-sketch

Velg deltype

Velg ønsket deltype for å se forhåndsvist tegning av tekniske dimensjoner

Bracket Material
Material
Bushing Material
Carrying Capacity
Diameter
Plunger Diameter
Type Of Assembly
Type Of Tube
Diameter Bases
Connecting Thread
External Diameter
Handle
Hole
Lever Length
Wheel Base
Threaded Screw
Hole Distance
Threaded Connection
Type Of Bellow
Type Of Vacuum Cups Holder
Vacuum Cup Holders Dimension
Vacuum Cups Dimension
Connector

Viser alle 2 resultater

    Vennligst velg en deltype for å få relevante valg.

    Lukk
    Code 61011
    Description TVD.70-1 1/4-FKM-C7
    d
    —
    • —
    D
    —
    • —
    L
    —
    • —
    d1
    —
    • —
    d2
    —
    • —
    h
    —
    • —
    Weight
    —
    • —
    CAD
  • Code 61011
    Description TVD.70-1 1/4-FKM-C7
    d G 1 1/4
    D 70
    L 59
    d1 33
    d2 68.5
    h 17
    Weight 80
  • Code 61021
    Description TVD.70-1 1/4-EPDM-C6
    d G 1 1/4
    D 70
    L 59
    d1 33
    d2 68.5
    h 17
    Weight 80
Main specifications
Material

Polypropylene-based (PP) technopolymer.

  • Cover: red colour (TVD-EPDM), green (TVD-FKM).

Graphic symbol "valve" tampoprinted in black colour.

Avoid contact with solvents, alcohol or detergents containing alcohol to preserve tampoprinted graphic symbol.

On request, the cover can be also supplied in black colour, with graphic symbol valve tampoprinted in other colour.

  • Threaded connector: black colour.

Standard executions

  • TVD-FKM: flat packing ring and FKM membrane gasket, hardness 70 Shore A.
  • TVD-EPDM: flat packing ring and EPDM membrane gasket, hardness 70 Shore A.

Maximum continuous working temperature

50°C.

General information
Features and applications

TVD. breather caps with vacuum breaker valve are suitable for reservoirs and tanks for liquid transport.

The membrane retaining system allows a quick emptying out of the reservoir by letting in big quantities of air through the cap. Thus avoiding the vacuum inside the reservoir, slowing down the liquid exit.

The pre-set pressure of the membrane gasket stops any liquid loss when the reservoir is shaken (for example during transportation).

The liquid pressure on the gasket guarantees a perfect seal of the cap, for example in case of overturning of the reservoir.

Resistance to chemical agents

Tests carried out under standard laboratory conditions at 23°C. Values to be considered only as guidelines.

Please contact ELESA Technical Department for further chemical resistance details to particular liquids not reported in the table.

DepressionLoad capacity
FKMEPDM
50 mb360 l/min370 l/min
40 mb320 l/min330 l/min
30 mb260 l/min280 l/min
20 mb210 l/min230 l/min
10 mb140 l/min160 l/min
5 mb110 l/min130 l/min
Handlekurv
Skroll til toppen